The aim of seasonal commissioning is to observe the building services when they are run at their full load and ensure they perform as the were designed to. This has proved to be a valuable and crucial service for all building types, a building with fewer defects performs better.
The continuous support of the commissioning team during the first year reduces the operation and maintenance costs as defects are identified and rectified earlier, increasing the systems’ life.
Training undertaken as part of the commissioning helps the building occupants and facilities managers better understand the functionality of the building and ensure it continues to perform at optimum levels.
[edit] When to consider
A commitment to carry out seasonal commissioning will be required at the design stage. Seasonal commissioning should commence during the first 12 months after the building is occupied and take place during full load conditions (i.e. heating equipment in mid-winter and cooling/ventilation during summer) and part load conditions (spring/autumn)
[edit] Step-by-step guidance
The requirements of this credit are an extension of the normal responsibilities for a contractor where there is a 12 months defects period in place under the contract and contributes to providing a 'soft landing' for the client/occupier.
The contractor is required to confirm that a specialist commissioning manager has been appointed to carry out seasonal commissioning during the first 12 months after occupation. Under the BREEAM criteria, there are a number of systems defined as complex and it is unlikely that a single person will have sufficient experience to undertake this role for all systems. Therefore the contractor may need to appoint more than one individual to this role.
Ideally, as part of the design stage, the contractor should nominate named individuals to undertake this role in particular where the Man 04 credit on commissioning building services has been targeted as the same people can carry out both roles. However, if this is not appropriate, commitment to make the appointment would be sufficient.
For simple systems, this role can either be undertaken by the contractor or the client/occupier can nominate an individual from within their facilities management team to undertake the required activities. Where the client/occupier has nominated an individual to monitor the commissioning of the systems on their behalf, this person could also perform this role.
[edit] Questions to ask while seeking compliance
- Are complex systems present within the building design?
- Can the role of the specialist commissioning manager appointed for Man 04 be extended to meet the requirements of this credit?
[edit] Tools and resources
- BSRIA Commissioning guides and CIBSE Commissioning codes.
- Knowledge Base Link for Man05: Aftercare: https://kb.breeam.com/section/new-construction/uk/2014-uk/management-breeam_uk_nc_2014/man05/
[edit] Tips and best practice
Where a building management system (BMS) is specified the following procedures should be carried out:
- The occupier is fully trained in the operation of the system.
- All BMS graphics and schematics are fully functional and installed to user interface before handover.
- The BMS/ controls installation should be running in auto with satisfactory internal conditions prior to handover.
- In addition to air and water flow results, commissioning results include physical measures of air temperatures, off coil temperatures and other key parameters as appropriate.
- Commissioning of air and water systems is carried out when all control devices are installed, wired and functional.
[edit] Typical evidence
[edit] Design stage
A specification, contract clauses or appointment letter confirming the commitment to carry out commissioning during the first 12 months of occupation. Where complex systems are installed, a specialist commissioning manager must be appointed.
[edit] Post construction
Copies of an appointment letter confirming seasonal commissioning responsibilities and seasonal commissioning schedules confirming what will be commissioned and when. Where seasonal commissioning has already taken place due to the timing of the post construction assessment, records and reports to confirm this has taken place should be provided.
[edit] Applicable Schemes
The guidelines collated in this ISD aim to support sustainable best practice in the topic described. This issue may apply in multiple BREEAM schemes covering different stages in the life of a building, different building types and different year versions. Some content may be generic but scheme nuances should also be taken into account. Refer to the comments below and related articles to this one to understand these nuances. See this document for further guidelines.
- BREEAM UK New Construction 2014
- BREEAM UK Refurbishment and Fit-Out 2014
This article was originally created in a BREEAM Professionals workshop by Jane Morning, Tom Blois-Brooke, Tom Abbott and Azita Dezfouli.
BRE Global does not endorse any of the content posted and use of the content will not guarantee the meeting of certification criteria.
--Multiple Author Article 16:26, 19 Apr 2018 (BST)
[edit] Related articles on Designing Buildings Wiki
- Advantages of shell and core.
- At your services - What to expect during commissioning.
- Client commissioning.
- Commissioning.
- Commissioning documents.
- Commissioning notice.
- Commissioning plan.
- Commissioning planning.
- Commissioning v testing.
- Continuous commissioning.
- Corrosion in heating and cooling systems.
- Handover to client.
- Initial commissioning case studies.
- Seasonal and continuous commissioning.
- continuous commissioning
- Soft landings.
- Specialist commissioning manager.
Featured articles and news
Shortage of high-quality data threatening the AI boom
And other fundamental issues highlighted by the Open Data Institute.
Data centres top the list of growth opportunities
In robust, yet heterogenous world BACS market.
Increased funding for BSR announced
Within plans for next generation of new towns.
New Towns Taskforce interim policy statement
With initial reactions to the 6 month policy update.
Heritage, industry and slavery
Interpretation must tell the story accurately.
PM announces Building safety and fire move to MHCLG
Following recommendations of the Grenfell Inquiry report.
Conserving the ruins of a great Elizabethan country house.
BSRIA European air conditioning market update 2024
Highs, lows and discrepancy rates in the annual demand.
50 years celebrating the ECA Apprenticeship Awards
As SMEs say the 10 years of the Apprenticeship Levy has failed them.
Nominations sought for CIOB awards
Celebrating construction excellence in Ireland and Northern Ireland.
EPC consultation in context: NCM, SAP, SBEM and HEM
One week to respond to the consultation on reforms to the Energy Performance of Buildings framework.
CIAT Celebrates 60 years of Architectural Technology
Find out more #CIAT60 social media takeover.
The BPF urges Chancellor for additional BSR resources
To remove barriers and bottlenecks which delay projects.
Flexibility over requirements to boost apprentice numbers
English, maths and minimumun duration requirements reduced for a 10,000 gain.
A long term view on European heating markets
BSRIA HVAC 2032 Study.
Humidity resilience strategies for home design
Frequency of extreme humidity events is increasing.
National Apprenticeship Week 2025
Skills for life : 10-16 February